Table 3. Volumetric shrinkage of round timber by various pretreatments
Sample
Volume before drying (m
3
)
Volume after drying (m
3
)
Shrinkage (%)
C
0.0993
0.0973
2.02
ES
0.0980
0.0956
2.50
ES-K
0.0981
0.0956
2.60
LS-ES-B
0.0974
0.0931
4.70
LS-PES
0.1003
0.0968
3.62
C: control, ES: end sealing, ES-K: end sealing - kerfed, LS-ES-B: lateral sealing - end sealing - boring, LS-PES: lateral sealing - partitional end sealing.